husky 60 gallon air compressor manual

husky 60 gallon air compressor manual

. This warranty applies only to the original retail purchaser and may not be transferred. Operation (continued) 2 Checking the safety valve (Figure 5) DANGER: Do not tamper with the safety valve. . Vérifiez les connexions du câblage dans le pressostat et la boîte à bornes. Condensation d’eau. Check the torques of the head bolts after the first five hours of operation. Service Parts - Compressor MODEL VT631404 32 29 30 25 31 28 27 33 4 3 17 23 5 26 10 19 24 21 7 22 34 11 12 2 24, Service Parts - Compressor (continued) Part Description Part Number Quantity 1 Tank AR060300CG 1 2 Drain valve D-1403 1 3 Electric motor MC019000SJ 1 4 Key KE000900AV 1 5 Hex head screw ST016000AV 4 6 Washer ST011200AV 4 7 Locknut ST146001AV 4 8 Nipple HF002401AV 1 9 Pressure switch CW209300AV 1 10 Motor cord EC012800AV 1 11 ASME Safety valve V-215105AV 1 12 Plug ST022500AV 1 13 Gauge GA031900AV 1 14 Unloader valve CW210001AV 1 15 Check valve CV2, Service Parts - Pump MODEL VT472200AJ 14 15 18 13 12 16 17 19 11 20 21 22 10 9 7 23 8 24 26 6 25 5 4 2 3 2 27 1 26 28. Thread a nut onto each bolt until the top of the nuts and bolts are flush. The Typical Compressed Air Distribution System provides a guideline. This warranty applies only to the original retail purchaser and may not be transferred. No hay energía eléctrica. 155 PSI maximum working pressure allows the user optimum tool performance. It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F. •CFM at 40 psi is 13.4 and CFM at 90 psi is 11.5 Place a flathead screwdriver into the raised notch, and tap the screwdriver with a hammer until tight. Article # 911625 Modèle # C601H GUIDE D’UTILISATION ET D’ENTRETIEN COMPRESSEUR D’AIR FIXE DE 227 LITRES (60 GALLONS) Questions, problèmes, pièces manquantes? Make sure all the equipment is properly grounded. WARNING: Risk of electrical shock. Table of Contents Safety Information . . Since the air compressor and other components (material pump, spray guns, filters, lubricators, □ Place a washer on each bolt. La polea está desalineada. Never use reducers in discharge piping. Si el aire continúa saliendo después de soltar el aro de la válvula de seguridad, no uses la unidad y busca ayuda profesional antes de reaudar el uso del compresor de aire. Connexions électriques lâches. réservoir est insuffisante. Before returning to the store, call Husky Customer Service 8 a.m.-6 p.m., EST, Monday-Friday 1-888-43-HUSKY HUSKYTOOLS.COM Retain this manual for future use. Search within model. Electric Air Compressor-VT6314 - The Home Depot . 5 Electrical Safety . Reportezvous au paragraphe Vérification de la soupape de sûreté. 2. Utilisation (suite) 4. . . pts-205109-051012, pts-2053019-053012, pts-206067-060612 Parts List - Unit Assembly ITEM NUMBER PART NUMBER QUANTITY 1 E105987 1 DESCRIPTION BELTGUARD (OUTER) 2 NA 5 #10 PLASTITE SCREW 3 NA 9 BOLT, 5/16-18 X 1.25 THR FORM 4 E105988 1 BELTGUARD (INNER) 5 NA 2 SETSCREW 6 NA 1 KEY 5MM X 20MM 7 E105989 1 BELT 4L-520 "A" SECTION 8 E105990 1 PULLEY 9 E105991 1 CORD INTERCONNECT 10 NA 4 BOLT 5/16-18 X . Antes de regresar a la tienda, llama al Servicio al Cliente de Husky de Lunes a Viernes entre 8 a.m. y 6 p.m., (hora del Este de EE. ADVERTENCIA: Riesgo de explosión. . BelAire/IMC Owners Manuals. View and Download Husky 80-GALLON STATIONARY AIR COMPRESSOR use and care manual online. Defective check valve or unloader. Husky 60 gallon single stage stationary electric air compressor features a cast iron, oil lubricated pump. pts-205109-051012, pts-2053019-053012, pts-206067-060612 8. Este procedimiento es necesario antes de poner a funcionar el compresor de aire y cuando haya sido reemplazada la válvula de retención o la bomba del compresor. 0,38 m3/min (13,4 pi3/min) à 276 kPa (40 psi) 0,32 m3/min (11,5 pi3/min) à 620 kPa (90 psi) Huile de graissage 240 V, 60 Hz, c.a. . Download. . . Si un entretien supplémentaire est nécessaire, veuillez composer le 1-888 43 HUSKY pour une assistance supplémentaire. Hay carbono acumulado en la bomba. . Solution □ Check incoming voltage. 60 Hz, 1 Phase Width 20 in. 1. Air compressor Head Bolts - Torquing The air compressor pump head bolts should be kept properly torqued. . . . . Ajax Owners Manuals. WARNING: Risk of unsafe operation. MISE EN GARDE : Ne tentez pas de modifier cet outil ou de créer des accessoires dont l’utilisation n’est pas recommandée avec cet outil. . This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations. Consultez les codes locaux pour les calibres de fil recommandés, le calibre de fil correct et la longueur de fil maximum; des câbles d’un trop petit calibre causeront un débit en ampères trop élevé et une surchauffe du moteur. . Turn air compressor off, lock out the power supply, and relieve all air pressure from the air tank. pts-205109-051012, pts-2053019-053012, pts-206067-060612 Prise d’air réduite. Owners manual and parts breakdown for Husky Air Compressors. El fusible de la casa/taller Reemplaza el fusible de la casa/ está fundido. NOTE: Do not overtighten. 29 HUSKYTOOLS.COM Veuillez composer le 1 888 43-HUSKY pour une assistance supplémentaire. Failure to heed this warning could result in death or serious personal injury. . . . ........BB Part BB CC DD Description Concrete Anchors 3/8” Lag Screw to fit concrete anchors Shims ........CC Quantity 4 4 as needed Package Contents HARDWARE INCLUDED NOTE: Hardware not shown to actual size. Product Overview Designed with performance and durability in mind, the Husky 60 Gal., 2-Stage Portable Air Compressor offers up to 175 psi and plenty of air flow at 7.6 SCFM at 90 psi to power a wide variety of air tools. Husky Air Compressor Operator's Manual. Low voltage could be due to wires (from electrical source to compressor) being too small in diameter and / or too long. □ Shift the motor towards the pump. Use air compressor oil only. Des équipements supplémentaires seraient nécessaires pour filtrer et purifier l’air correctement afin de satisfaire les critères minimaux de l’air respirable de Grade D tels que décrits dans la norme Commodity Specification G 7.1 établie par la Compressed Gas Association - 1966, OSHA 29 CF9 1910.134. Set the Auto/Off switch (A) to “On”. 4 Vérifiez la soupape de sûreté. . Previous. 6. . Aucun courant électrique. . Funcionamiento (continuación) 4 Cómo comenzar (Figura 2) 1. Poulie mal alignée. quality products designed to enhance your home. Safety Information (continued) 2. Válvula de Drenaje: La válvula de drenaje está ubicada en la base del tanque de F aire y se usa para drenar la condensación después de cada uso. . Appliquez un couple de 27,1 à 33,9 Nm (20 à 25 pi-lb). . . . Si es necesario, quita el tapón de llenado de aceite (L) y agrega aceite lentamente hasta que alcance el medio de la mirilla. . Table des matières Consignes de sécurité......................... 2 Garantie............................................... 7 Sécurité de l’aire de travail..............2 Caractéristiques.................................. 8 Sécurité de l’utilisateur ...................3 Cycle de service................................... 8 Transport.........................................3 Outils requis........................................ 9 Sécurité du compresseur d’air et des outils pneumatiques............... Consignes de sécurité (suite) être utilisé(e) pour fournir de l’air respirable. Verifica el nivel de aceite de la bomba. . El compresor debe estar correctamente montado. . Sistema de distribución de aire ADVERTENCIA: Riesgo de explosión. ATTENTION : Maintenez le filtre à air propre en permanence. . If the compressor is left in the AUTO position and air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. Caractéristiques COMPRESSEUR D’AIR Puissance de fonctionnement en cheval-vapeur Capacité du réservoir d’air Pression d’air Débit d’air Lubrification Entrée 3,7 CV 227 litres (60 gal) 1068 kPa (155 PSI) max. Page 1. Ne pulvérisez pas de l’air non filtré sur un objet qui pourrait être endommagé par l’humidité. Compressor will remain hot for several minutes after operation. Item # 1000 710 098 Model # VT631404 USE AND CARE GUIDE 60-GALLON STATIONARY AIR COMPRESSOR Questions, problems, missing parts? When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pressure to remain inside the air tank. Ne soudez ni ne percez jamais des trous dans le réservoir d’air. info on the compressor : Husky 60 gal. . Maintenance (continued) 1 Oil (Figure 6) CAUTION: Overfilling with oil will cause premature air compressor failure. . . Package Contents (continued) Part F G H I J K L M N O P Description Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. The supply line should have the same electrical characteristics (voltage, cycle, phase) as the motor. Contact a call Husky Customer Service for more information. See Prices; Husky Air Compressor D29616. Shorted or open motor winding. Husky 60 Gal. WARNING: All wiring and electrical connections must be performed by a qualified electrician familiar with industrial motor controls. This unit can start automatically without warning. VIS : Des fuites mineures A peuvent entraîner un surmenage du compresseur d’air, et résulter dans des pannes prématurées ou un rendement inadéquat. 2. 155 PSI max pressure allows the user optimum tool performance. Title: Husky 60 gallon air compressor manual, Author: mailed89, Name: Husky 60 gallon air compressor manual, Length: 3 pages, Page: 1, Published: 2018-01-02 Issuu company logo Issuu Coloca el compresor de aire alejado al menos 18 pulgadas (0,5 m) de paredes u obstrucciones que pudieran interferir con el flujo de aire. Before returning to the store, call Husky Customer Service 8 a.m. - 6 p.m., EST, Monday - Friday 1-888-43-HUSKY HUSKYTOOLS.COM THANK YOU We appreciate the trust and confidence you have placed in Husky through the purchase of this air compressor. Funcionamiento (continuación) OTA: Todos los sistemas de N aire comprimido generan líquido de condensación que puede acumularse en cualquier punto de drenaje (por ejemplo, tanques, filtro, enfriadores, secadores). 1. Share. . ........BB Pièce BB CC DD ........CC Description Chevilles pour béton Tire-fond 9,5 mm (3/8 po) correspondant aux chevilles pour béton Cales ........ Contenu de l’emballage (suite) Familiarisez-vous avec ces commandes avant d’utiliser l’appareil (Figure 2) FIGURE 2 K I L O E G N M FIGURE 7 H C A D B P J F Pièce Description INTERRUPTEUR AUTO(I)/ARRÊT(0) : Mettez cet interrupteur dans la position «Auto A (I)» pour fournir une alimentation électrique continue au pressostat et sur la position «Arrêt (0)» pour couper l’alimentation électrique à la fin de chaque utilisation. 2 NOTE: Use SAE 30 industrial grade air compressor oil or full synthetic motor oil like Mobil 1® 10W30. Ce compresseur d’air est alimenté par un moteur électrique construit avec précision. □ There are too many devices on the same circuit. This air compressor unit can be installed as part of an air distribution system. User manuals, Husky Air Compressor Operating guides and Service manuals. Huile perdue dans la pompe. Solución Cuando disminuya la presión del tanque, el compresor se encenderá para acortar la presión de arranque. □ Reattach the air filter cover (3). 1 Checking and changing the oil Maintain the proper oil level by checking the oil sight glass (1) daily. Courroie desserrée. Mantenimiento (continuación) 2 Revisar 1. single stage stationary electric air compressor features a cast iron, oil lubricated pump. 2. Maintenance (continued) 4 5 Checking the belt □ Remove the beltguard screw (1). . Consignes de sécurité (suite) SÉCURITÉ ÉLECTRIQUE (BRANCHEMENTS ÉLECTRIQUES) 1. . A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. Quand la tension correcte de la courroie est obtenue, serrez les quatre vis de montage du moteur. La pompe du compresseur n’a aucune huile. La polea está floja. . Since the air compressor and other components (material pump, spray guns, filters, lubricators, 2. Purgez l’eau du réservoir d’air. . Item # 911625 Model # C601H USE AND CARE GUIDE 60 GALLON STATIONARY AIR COMPRESSOR Questions, problems, missing parts? Bomba de Compresión de Aire: Aire comprimido en el tanque de aire. 2. 5. 1. . 1. Cuando la presión del tanque llegue a la presión de “parada”, abre la válvula de liberación de aire. . 2. 1 □ Set the cover aside until wiring is completed. A pesar de la clasificación de presión indicada, la tubería de plástico puede explotar por la presión del aire. . Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment. . Loose electrical connections. . Do not use on a ladder or unstable support. Son grinçant. □ The air intake is restricted. . Reportez-vous à Purge du réservoir dans la section Utilisation. Pages: 60. Max. Have a qualified electrician check these conditions and make repairs as needed. WARNING: Disconnect, tag, and lock out the power source, and then release all pressure from the system before attempting to install, service, relocate, or perform any maintenance. 80-GALLON STATIONARY AIR COMPRESSOR. Husky C601H Use And Care Manual (28 pages) 60 GALLON STATIONARY AIR COMPRESSOR Brand: Husky | Category: Air Compressor | Size: 2.37 MB MISE EN GARDE : Risque d’éclatement. Air tanks contain high pressure air. Operation 1 Draining the tank (Figure 2, 4) OTICE: All compressed air N systems generate condensate that accumulates in any drain point (e.g., tanks, filter, aftercoolers, dryers). taller. Entretien (suite) 2 4 Filtre à air MISE EN GARDE : Surfaces chaudes. 3. Personal injury and / or equipment damage may occur. . Système de distribution d’air (suite) • Si la conduite a plus de 30,5 m (100 pi) de long, utilisez une conduite de la grosseur suivante. Información de seguridad (continuación) SEGURIDAD DE LA HERRAMIENTA NEUMÁTICA Y COMPRESOR DE AIRE TRANSPORTABLE 7. Assembly 1 Assembling the air compressor unit WARNING: Never use plastic (PVC) pipe for compressed air. • Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. 2. This output can definitely maximize the performance of your pneumatic tools. The unit must be bolted to the floor with isolation pads before operating to prevent equipment damage, injury, or death. L’utilisation de toute autre pièce peut créer un risque ou endommager le produit. Wear safety glasses and use hearing protection when operating the unit. Coloca el interruptor Auto/Off (A, Figura 2) en “Auto” y deja que la presión del tanque se acumule. . Operation (continued) 4 How to start (Figure 2) 1. It has a big 60 gal tank with a cast iron, twin-cylinder compressor pump. 2 General Safety . . Verifica la conexión del cableado del interruptor de presión y la caja de distribución. You have come to the right place if you need to repair your C602H Husky 60 Gallon Air Compressor or looking for the Husky 60 Gal Air Compressor C602H Parts. Change the oil in the pump every 3 months. Les éléments desserrés de ce dispositif pourraient être projetés et vous frapper. Safety Information (continued) GENERAL SAFETY DANGER: Breathable Air Warning: This compressor/pump is NOT equipped and should NOT be used “as is” to supply breathing quality air. Husky 60 gallon air compressor C601H also has a heavy duty induction motor that has a power output of 3.7 horsepower. 2. . The knob must be in the same position as when removed to sit correctly in place. Vista ampliada - ensamblaje, motor/bomba NOTES: Torque to 25-27 lb-ft. Serrez de 25 À 27 lbs-ft. Torsión hasta 33,9-36,6 N•m Torque to 14-16 lb-ft. Serrez de 14 À 16 lbs-ft. Torsión hasta 19,0-21,7 N•m Torque to 9-12 lb-ft. Serrez de 9 À 12 lbs-ft. Torsión hasta 12,2-16,3 N•m Torque to 8 lb-ft. Serrez de 8 lbs-ft. Torsión hasta 10,9 N•m pts-205109-051012, pts-2053019-053012, pts-206067-060612 Torque to 5 lb-ft. Serrez de 5 lbs-ft. Torsión hasta 6,8 N•m 23 HUSKYTOOLS.

Thirumanam Ennum Nikkah Full Movie Hotstar, App Games For Long Distance Couples, Bluey Season 2 Episode 1, Th9 Anti 3 Star Base 2020, Inference Question Stems Ks2, International Longshoremen's Association Logo, Mizu Mizu No Mi, Du Pg Admission 2020 Application Form, Jeremy Buendia Net Worth,

اترك تعليقاً

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مشار إليها بـ *